TRIPP LITE 2U 8-OUTLET 'SMART-PRO' LINE-INTERACTIVE UPS (1350W/1500VA) - RACKMOUNT
https://www.linhawstore.com/shop/trs1500rm-tripp-lite-2u-8-outlet-smart-pro-line-interactive-ups-1350w-1500va-rackmount-3118 https://www.linhawstore.com/web/image/product.template/3118/image_1920?unique=1ed7399
                Terms and Conditions
                30-day money-back guarantee
                Shipping: 2-3 Business Days
            
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface
Offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot.
95% line-mode efficiency offers reduced heat emissions and operating costs.
Network management interfaces support communications via USB, RS-232 and optional SNMPWEBCARD network interface. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions.
Includes PowerAlert monitoring software and complete cabling.
Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test.
Field-replaceable, hot-swappable battery modules.
Key Features:
- Tripp Lite SMART1500RM2U line interactive 2U rack/tower UPS with 1500VA / 1.5kVA / 1350W capacity 
- Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 147V 
- NEMA 5-15P input plug; 6 NEMA 5-15R output receptacles, Two independently switchable output load banks 
- Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages 
- High 95% efficiency rating in line-power mode offers reduced power consumption and BTU emissions 
- Internal batteries offer 13 minutes at 50% load (675W) and 4.5 minutes at 100% load (1350W) 
- Hot-swappable, user-replaceable internal batteries can be replaced with no disruption to connected equipment 
- Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information 
- LCD interface also supports a number of advanced user setup and operating preferences 
- Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; 
- Optional 2-9USTAND enables tower placement 
- Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options 
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X 
- Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable 
Package Includes
- SMART1500RM2U UPS System 
- PowerAlert software with USB, Serial & EPO cabling 
- 4 post rackmount installation kit 
- Instruction manual 
Specifications:
| OUTPUT | |
| Output Volt Amp Capacity (VA) | 1500 | 
| Output kVA capacity (kVA) | 1.5 | 
| Output Watt Capacity (watts) | 1350 | 
| Output kW capacity | 1.35 | 
| Output power factor | 0.9 | 
| Nominal Output Voltage(s) Supported | 120V | 
| Frequency compatibility | 60 Hz | 
| Output voltage regulation (line mode) | -21%, +8% | 
| Output voltage regulation (Battery mode) | +/- 5% | 
| Built-in UPS output receptacles | 8 5-15R outlet(s) | 
| Built-in controllable switched load banks | Two switchable two-outlet 5-15R load banks | 
| Output AC waveform (AC mode) | Sine wave | 
| Output AC waveform (battery mode) | Pure Sine wave | 
| INPUT | |
| Rated input current (at maximum load) | 12A | 
| Nominal Input Voltage(s) Supported | 120V AC | 
| UPS input connection type | 5-15P | 
| Input circuit breaker | 15A | 
| UPS Input cord length (ft.) | 10 | 
| UPS Input cord length (m) | 3 | 
| Recommended Electrical Service | 15A 120V | 
| BATTERY | |
| Full load runtime (minutes) | 4.5 min. (1350w) | 
| Half load runtime (minutes) | 13 min. (675w) | 
| DC system voltage (VDC) | 36 | 
| Battery recharge rate (included batteries) | Less than 4.5 hours from 10% to 90% | 
| Replacement battery cartridge (internal UPS battery replacement) | RBC93-2U | 
| Battery Access | Front panel battery access door | 
| Battery replacement description | Hot-swappable, user replaceable batteries | 
| VOLTAGE REGULATION | |
| Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147 | 
| Overvoltage correction | Input voltages between 128 and 147 are reduced by 12% | 
| Undervoltage correction | Input voltages between 83 and 107 are boosted by 14% | 
| LEDS ALARMS & SWITCHES | |
| Front panel LCD display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) | 
| Alarms | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions | 
| Alarm cancel operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available | 
| Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions | 
| SURGE / NOISE SUPPRESSION | |
| UPS AC suppression joule rating | 570 | 
| UPS AC suppression response time | Instantaneous | 
| EMI / RFI AC noise suppression | Yes | 
| PHYSICAL | |
| Installation form factors supported with included accessories | 4 post 19 inch rackmount (mounting rail kit included) | 
| Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) | 
| Primary form factor | Rackmount | 
| UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.5 x 17.5 x 13.45 | 
| UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.9 x 44.4 x 34.2 | 
| Installed whole system total rack space height (rack spaces) | 2U | 
| Secondary form factor | Tower (requires 2-9USTAND) | 
| UPS / Power Module weight (lbs) | 46.5 | 
| UPS / Power Module weight (kg) | 21.1 | 
| UPS Shipping dimensions (height x width x depth / inches) | 9 x 24 x 20.2 | 
| UPS Shipping dimensions (height x width x depth / cm) | 22.9 x 61 x 51.4 | 
| Shipping weight (lbs) | 57.6 | 
| Shipping weight (kg) | 26.2 | 
| UPS housing material | Steel | 
| Cooling method | Fan | 
| ENVIRONMENTAL | |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | 
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | 
| Relative Humidity | 0 to 95%, non-condensing | 
| AC mode BTU / hr. (full load) | 267 | 
| COMMUNICATIONS | |
| Communications interface | USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface | 
| Network monitoring port description | Supports detailed monitoring of UPS and site power conditions | 
| PowerAlert software | Included | 
| Communications cable | USB and DB9 cabling included | 
| WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications | 
| LINE / BATTERY TRANSFER | |
| Transfer time | 2-4 milliseconds | 
| Low voltage transfer to battery power (setpoint) | 83 | 
| High voltage transfer to battery power (setpoint) | 147 | 
| SPECIAL FEATURES | |
| Grounding lug | Back panel grounding lug | 
| Cold Start (startup in battery mode during a power failure) | Cold-start operation supported | 
| High availability UPS features | Hot swappable batteries | 
| Green & high efficiency features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks | 
| CERTIFICATIONS | |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) | 
| WARRANTY | |
| Product Warranty Period (Worldwide) | 2-year warranty, 3 year with registration. Note: registration is required for 3-year warranty. | 
| Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance | 
Specifications
| Mounting Direction | Horizontal | 
| UPS Power | 1000W - 1499W | 
| Outlet Number | 8 | 
| Rack Unit | 2U | 
| Power Rating | 1350VA-1500VA |